Customization: | Available |
---|---|
CAS No.: | 9002-88-4 |
Formula: | -[-CH2-CH2-]N- |
Still deciding? Get samples of US$ 100/delivery cost to be discussed
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Property item | Test condition | Test method | Test data | Data unit |
MFR | 2.16kg | Q/SY DS 0511 | 7.3 | g/10min |
Density | Q/SY DS 0510 | 0.9566 | g/cm3 | |
Tensile yield stress |
Q/SY DS 0512 | 30.4 | MPa | |
Tensile stress at break |
Q/SY DS 0512 | 26.3 | MPa | |
Tensile stain at break |
Q/SY DS 0512 | 1481 | % | |
IZOD Impact Strength |
GB/T 1043.1-2008 | 5.8 | kJ/m2 |
Item | Test method | Test data | Data unit |
Density | 0.955 | g/cm3 | |
MFR(190ºC,2.16KG) | 0.35 | g/10min | |
Tensile yield strength | 27 | Mpa | |
flexural modulus | 1370 | Mpa | |
Elongation at break | ≥600 | % | |
Brittle temperature | ≤-75 | ºC |
Project performance | Test conditions [state] | Test method | Test data | Data unit |
Density | ASTM D-1505 | 0.946 | g/cm3 | |
Melt flow rate |
190ºC/2.16kg | ASTM D-1238 | 0.18 | g/10min |
190ºC/21.6kg | ASTM D-1238 | 15 | g/10min | |
Flexural modulus | ASTM D-790 | 1150 | MPa | |
Falling dart impact strength | ASTM D-1709 | 90 | g | |
Tensile yield strength |
ASTM D-882 |
MD,24 | MPa |
|
TD, 26 | ||||
Elongation at break |
ASTM D-882 |
MD,480 | % |
|
TD, 640 | ||||
Brittle temperature |
ASTM D-746 |
<-75 | ºC |
|
Elleman, torn apart |
ASTM D-1922 |
MD,19 | g |
|
TD,270 |